Why it stands out
Best for
Not ideal for
Why buy from EMiUZEK
We help you choose, connect and maintain your system—not just ship a box.
- ✓Authentic products
- ✓Compatibility guidance
- ✓Fast tracked shipping
- ✓Firmware and driver support
- ✓Clear warranty process
- ✓Responsive after-sales help
How to connect
EMiUZEK buying notes
Frequently asked questions+
View full technical specifications+
Official product information provided by LHY Audio+
The following product descriptions, specifications and images are provided by the manufacturer.
LHY Audio OCK-2P is a platinum-grade 10MHz master clock generator with six independently driven sine- and square-wave outputs. Its selected OCXO, isolated thermal chamber, two-stage regulation and selectable grounding target reference digital audio systems that demand the lowest close-in phase noise.
Why it stands out
-115dBc close-in phase noise
The selected OCXO reaches a guaranteed -115dBc at 1Hz offset.
Six flexible clock outputs
Three sine and three square outputs include both 50-ohm and 75-ohm connections.
Thermally controlled clock core
An independent chamber stabilizes the OCXO operating environment.
Upgraded power and grounding
A 30VA transformer, LM350T/LT3041 regulation and float/ground control support system integration.
Best for
- Reference DAC, streamer and transport systems
- Systems clocking several compatible components
- Users needing both 50-ohm and 75-ohm outputs
- Systems requiring sine and square 10MHz signals
Not ideal for
- Equipment without a 10MHz clock input
- Users unsure of required impedance or waveform
- Systems needing 44.1kHz or word-clock output
- Portable or battery-powered setups







EMiUZEK Buying Notes
- Verify every receiving device requires 10MHz and confirm impedance, waveform and accepted level.
- OCK-2P does not carry audio; it supplies a timing reference only.
- Allow at least 15 minutes warm-up and approximately 60 minutes for full thermal stability.
Frequently asked questions
Does it improve every digital device?
Only equipment with a compatible 10MHz clock input can use it.
Can all six outputs operate together?
Yes, the distribution stage is designed for multiple outputs.
Which cable impedance should I use?
Match the receiving device: 50 ohms or 75 ohms.
Does it output sine and square wave?
Yes, three of each.
How long should it warm up?
15 minutes basic, about 60 minutes full.
Can it replace a word clock?
No. It is a 10MHz reference, not an audio word-clock generator.
HOW TO CONNECT
Single DAC
Source: OCK-2P
Connection: Correct 50/75-ohm BNC cable
Output connection: 10MHz sine or square
Target: Compatible DAC
Clocked streamer and DAC
Source: OCK-2P
Connection: Two independent BNC outputs
Output connection: Matched impedance
Target: Streamer and DAC
Multi-component system
Source: OCK-2P
Connection: Up to six independent outputs
Output connection: Device-specific waveform and impedance
Target: Compatible switch, transport and DAC
Technical Specifications
| Feature | Specification |
|---|---|
| Frequency | 10MHz |
| Outputs | 6: 3 square wave and 3 sine wave |
| Impedance | 50Ω ×2 and 75Ω ×1 per waveform |
| Output level | Square 2Vpp/1Vrms; sine 2.8Vpp/1Vrms at 50Ω |
| Phase noise | ≤-115dBc at 1Hz; ≤-140dBc at 10Hz |
| Stability | <±5ppb |
| Accuracy | <±0.05ppm |
| Dimensions | 240 × 175 × 50mm |
| Weight | 2.0kg |
Additional Product Content
📊 Comparison: OCK-2P or OCK-2S — Which Master Clock Is Right for You?
Choose OCK-2P for the lowest phase noise, upgraded thermal/power architecture and selectable grounding; OCK-2S retains the same six-output flexibility at a lower system cost.
| Feature | OCK-2P | OCK-2S |
|---|---|---|
| Position | Platinum reference | Reference |
| Phase noise at 1Hz | ≤-115dBc | Typical -110dBc |
| Transformer | 30VA | 15VA |
| Regulation | Two-stage LM350T + LT3041 | Low-noise linear supply |
| OCXO chamber | Independent thermal chamber | Standard internal compartment |
| Ground control | Selectable float/ground | Individual output ground controls |
| Best use | Maximum timing refinement | High-value multi-device clocking |
What's in the box, manuals and downloads+
- LHY Audio OCK-2P Master Clock ×1
- AC Power Cable ×1
- Product Documentation ×1
Shipping, warranty and returns+
発送元と配送費用
ご注文は中国本土の蘇州から発送します。
配送料と購入手続き時に徴収する税金は、お支払い前に表示します。配送先、重量別送料、輸入時の費用は配送・税金ポリシーをご確認ください。
EMiUZEK の商業保証
EMiUZEK は店舗の商業保証を提供します。DAC、アンプ、IEM、ドングルは1年間、ケーブルとアダプターは3か月間です。この保証は Yangzhong Jindun Digital Technology Co., Ltd. が提供します。メーカー保証がある場合は別途適用され、各ブランドの条件に従います。この商業保証は、法律上の強行的な権利や救済を制限しません。
返品
対象商品の返品は、お受け取りから30日以内にお申し込みください。不良ではない商品は、未使用または開封済みでも新品同様の状態であれば対象です。返送前にお問い合わせください。条件、例外、費用は返品ポリシーをご確認ください。
Premium 10MHz clock, thermal stabilization works well, great for multi-device digital audio setups.
This LHY Audio OCK-2P platinum-grade master clock is a serious upgrade for my high-end digital stack. The -115dBc phase noise spec paired with the isolated thermal chamber makes a clear difference. Six outputs mix sine and square wave, supporting both 50-ohm and 75-ohm gear. The two-stage power regulation and configurable grounding tame noise beautifully. After installation, the black background is deeper, micro-details emerge, and vocal timbre is far more natural.